Design properties 16 floor span and load tables 17 allowable holes 18 roof span and load tables 19 cantilevers 20 21 framing connectors 22 23.
Roof sheeting span tables.
For commercial and industrial applications tables are based on a maximum overall height of ten metres and a 500 year design return period.
Use the two span condition for support spacing greater than 32 inches on center but no greater than 48 inches on center.
Span tables are based on patio height and average roof heights as specified in the empty under and blocked under selection tables.
Use of these span tables requires reference to the applicable design values for the various species and grades of lumber.
Two or more sides open roof cladding adjacent to an open side to be at least 500mm from adjacent building or boundary.
Modulus of elasticity e bending design values f b.
Floor or roof sheathing conforming with this table shall be deemed to meet the design criteria of section 2304 7.
Non cyclonic area these span tables are for use in non cyclonic areas as defined by as 1170 2 2011 connections.
For domestic applications the pressures and spans are based on a maximum.
Effects of support width have been considered when determining the loads based on shear and deflection.
Span table the maximum recommended support spacings are based on testing in accordance with as1562 1 1992 as4040 1 1992 and as4040 2 1992.
The tables do not apply directly to panels having a single span.
Installation details shall conform to sections 2304 7 1 and 2304 7 2 for floor and roof sheathing respectively.
These span tables are to be used for structures that fall within the definition of open buildings i e.
For heights outside these ranges contact stramit for further information.
The tables permit a bearing length of up to 3 5 inches but since 1 5 is probably the worst case that you ll encounter for joist or rafter bearing it s a safe value.
Roof spans consider both resistance to wind pressure and light roof traffic traffic arising from incidental maintenance.
Average roof height between 3m and 6 5m 3m h 6 5m.
For strength axis parallel to supports tables are based on three spans for spans of 16 inches or less and two spans for 24 inches.
When the panel strength axis is placed parallel to framing supports the three span condition is used for support spacing up to and including 16 inches on center.
Floor span and load tables 7 8 tips for preventing floor noise 8 allowable holes 9 cantilevers 10 11 roof span and load tables 12 13 framing connectors 14 15 section 2.
1 inch 25 4 mm.
Maximum patio height hc is 3 2m.
Table 9 1 in span tables for joists and rafters figure 5 gives a required compression value of 237 psi for a span of 16 feet and bearing length of 1 5 inches.