Equipment not listed in tables above shall be limited to 10 of total building system capacity reduced lighting power per c406 3 or whole building lpd determined using 90 of values in table c405 4 2 1 x floor area for the building types or using 90 by the space by space method in section c405 4 2.
Roof u value table.
U value requirement semi glazed doors 1 2 w m k.
For example a building with material with an r value of r 11 converts to an u value of 0 09 1 r or 1 11 0 09.
The tables below show the suggested u values in england wales and scotland.
These r values were taken from manufacturer technical data sheets and are the reported r values per inch of actual products.
While the values do vary for each particular material and method of construction the following table gives general figures for some common modes of construction.
Notes to the table above.
The following table provides typical r values and rsi for various materials.
U value requirement windows whole window u value 1 4 w m k.
The r values for specific assemblies like doors and glazing in the table below are generalizations because they can vary significantly based on special materials that the manufacturer uses.
U value requirement opaque doors 1 0 w m k.
U value has an inverse relationship to r value.
Conservation of fuel and power approved document l1 24 l1 tables of u values table a2 indicative u values w m2 k for windows with metal frames 4mm thermal break gap between panes 6mm 12mm 16mm or more single glazing 5 7 double glazing air filled 3 7 3 4 3 3.
There are a few good u value calculators online that if you are short on time are worth checking out.
To learn more about r value see roof online s r value page.
These are expressed as a u value which needs to be achieved.
Notes on the r value k values of different forms of asbestos.
The required u value will depend on the location of the project england scotland or wales type of building domestic or non domestic and the application floor wall or roof.
Tables of building material r values.
R value of building materials material r inch r thick ness fiberglass inch 3 00 1 inch 4 00 inch 6 00 extruded polystyrene inch 3 75 1 inch 5 00 1 inch 7 50 foil faced polyisocyanurate inch 5 40 1 inch 7 20 1 inch 10 80 siding materials hardboard inch 0 34.
U values of typical building methods u values overall coefficient of heat transmission indicate the heat flow through materials the higher the figure the higher the heat loss.
U value requirement roof 0 13 w m k.
For instance using argon gas in a double pane insulating glass unit will dramatically improve the r value.